FOB Price : Get a Price/Quote
Min.Order : 1 Set(s)
Certification : CE
Brand Name : Kamoer
Payment Terms : T/T,PayPai
brand name : Kamoer
certification : CE
min.order : 1 Set(s)
warranty : 1 year
payment terms : T/T,PayPai
Packaging : Carton
Specification : KVP8 Plus
place of origin : Shanghai
The Kamoer KVP8 Plus is a compact dual-head diaphragm vacuum pump designed for gas transfer and vacuum generation in OEM equipment. Parallel and series configurations allow equipment manufacturers to choose between higher open-flow capacity and deeper vacuum performance.
Available with brushed or brushless DC motors and 12 V or 24 V operation, the KVP8 Plus is suitable for environmental monitoring, rehabilitation equipment, industrial automation, and household appliances.
Open-flow rate up to ≥11 L/min
Ultimate vacuum down to ≤-0.09 MPa
Parallel configuration for higher gas flow
Series configuration for deeper vacuum
12 V and 24 V options
Brushed and brushless DC motor options
Power consumption of 9 W
Compact dual-head structure
Designed for dry-running operation
EPDM diaphragm and valve materials
Reference product life up to ≥6,000 h with a brushless motor
Gas sampling in environmental monitoring equipment
Vacuum generation in rehabilitation equipment
Vacuum suction cups in industrial automation
Negative-pressure systems in massage devices
General OEM pneumatic equipment
Compact air-transfer systems
| Configuration | Motor | Voltage | Open Flow | Ultimate Vacuum |
|---|---|---|---|---|
| KVP8 Plus-KK | Brushed DC | 12 V | ≥10 L/min | ≤-0.07 MPa |
| KVP8 Plus-KJ | Brushed DC | 24 V | ≥10 L/min | ≤-0.07 MPa |
| KVP8 Plus-KD | Brushless DC | 12 V | ≥11 L/min | ≤-0.07 MPa |
| KVP8 Plus-KB | Brushless DC | 24 V | ≥11 L/min | ≤-0.07 MPa |
| KVP8 Plus-KK-S | Brushed DC, series | 12 V | ≥6.3 L/min | ≤-0.09 MPa |
| KVP8 Plus-KJ-S | Brushed DC, series | 24 V | ≥6.3 L/min | ≤-0.09 MPa |
| KVP8 Plus-KD-S | Brushless DC, series | 12 V | ≥6.6 L/min | ≤-0.09 MPa |
| KVP8 Plus-KB-S | Brushless DC, series | 24 V | ≥6.6 L/min | ≤-0.09 MPa |
| Parameter | Specification |
|---|---|
| Pump type | Dual-head diaphragm vacuum pump |
| Rated voltage | 12 V / 24 V |
| Power | 9 W |
| Control | On/off control |
| Brushed motor reference life | ≥2,000 h |
| Brushless motor reference life | ≥6,000 h |
| Parallel-model noise | ≤74 dB |
| Series-model noise | ≤72 dB |
| Brushed-model weight | Approx. 238 g |
| Brushless-model weight | Approx. 278 g |
| Operating temperature | 0–40°C |
| Relative humidity | <80%, non-condensing |
| Recommended tubing | 4 mm × 6 mm PU tubing |
Pump head: PA
Pump body: PA
Diaphragm: EPDM
Valves: EPDM
Eccentric mechanism: Metal
Reference performance was measured using air at 25°C, standard atmospheric pressure, and no load pressure. Noise was measured at a distance of 50 cm in a 35 dB ambient environment. Actual performance depends on atmospheric pressure, temperature, humidity, gas properties, tubing resistance, filters, voltage, and system load.
Positive-pressure operation is not recommended. Continuous operation above 0.02 MPa positive pressure may significantly reduce product service life. For dusty gas streams, an inlet filter should be installed to protect the pump.
Ordinary
verified
Business Type Manufacturer
Country / Region Shanghai,China
Main Products Medical Accessories
Main Markets European and American market
Brand : Kamoer
Min.Order : 1 Piece(s)
Brand : Kamoer
Min.Order :
Brand : Kamoer
Min.Order : 1 Piece(s)
Brand : Kamoer
Min.Order :
Brand : Kamoer
Min.Order : 1 Piece(s)
brand name : Kamoer
certification :
fob price :
min.order : 1 Set(s)
warranty : 1 year
payment terms : T/T,PayPai
Packaing : Carton
Specification : KVP8 Plus
Trademark : Kamoer
Production Capacity :
place of origin : Shanghai
Manag Certifica : CE
The Kamoer KVP8 Plus is a compact dual-head diaphragm vacuum pump designed for gas transfer and vacuum generation in OEM equipment. Parallel and series configurations allow equipment manufacturers to choose between higher open-flow capacity and deeper vacuum performance.
Available with brushed or brushless DC motors and 12 V or 24 V operation, the KVP8 Plus is suitable for environmental monitoring, rehabilitation equipment, industrial automation, and household appliances.
Open-flow rate up to ≥11 L/min
Ultimate vacuum down to ≤-0.09 MPa
Parallel configuration for higher gas flow
Series configuration for deeper vacuum
12 V and 24 V options
Brushed and brushless DC motor options
Power consumption of 9 W
Compact dual-head structure
Designed for dry-running operation
EPDM diaphragm and valve materials
Reference product life up to ≥6,000 h with a brushless motor
Gas sampling in environmental monitoring equipment
Vacuum generation in rehabilitation equipment
Vacuum suction cups in industrial automation
Negative-pressure systems in massage devices
General OEM pneumatic equipment
Compact air-transfer systems
| Configuration | Motor | Voltage | Open Flow | Ultimate Vacuum |
|---|---|---|---|---|
| KVP8 Plus-KK | Brushed DC | 12 V | ≥10 L/min | ≤-0.07 MPa |
| KVP8 Plus-KJ | Brushed DC | 24 V | ≥10 L/min | ≤-0.07 MPa |
| KVP8 Plus-KD | Brushless DC | 12 V | ≥11 L/min | ≤-0.07 MPa |
| KVP8 Plus-KB | Brushless DC | 24 V | ≥11 L/min | ≤-0.07 MPa |
| KVP8 Plus-KK-S | Brushed DC, series | 12 V | ≥6.3 L/min | ≤-0.09 MPa |
| KVP8 Plus-KJ-S | Brushed DC, series | 24 V | ≥6.3 L/min | ≤-0.09 MPa |
| KVP8 Plus-KD-S | Brushless DC, series | 12 V | ≥6.6 L/min | ≤-0.09 MPa |
| KVP8 Plus-KB-S | Brushless DC, series | 24 V | ≥6.6 L/min | ≤-0.09 MPa |
| Parameter | Specification |
|---|---|
| Pump type | Dual-head diaphragm vacuum pump |
| Rated voltage | 12 V / 24 V |
| Power | 9 W |
| Control | On/off control |
| Brushed motor reference life | ≥2,000 h |
| Brushless motor reference life | ≥6,000 h |
| Parallel-model noise | ≤74 dB |
| Series-model noise | ≤72 dB |
| Brushed-model weight | Approx. 238 g |
| Brushless-model weight | Approx. 278 g |
| Operating temperature | 0–40°C |
| Relative humidity | <80%, non-condensing |
| Recommended tubing | 4 mm × 6 mm PU tubing |
Pump head: PA
Pump body: PA
Diaphragm: EPDM
Valves: EPDM
Eccentric mechanism: Metal
Reference performance was measured using air at 25°C, standard atmospheric pressure, and no load pressure. Noise was measured at a distance of 50 cm in a 35 dB ambient environment. Actual performance depends on atmospheric pressure, temperature, humidity, gas properties, tubing resistance, filters, voltage, and system load.
Positive-pressure operation is not recommended. Continuous operation above 0.02 MPa positive pressure may significantly reduce product service life. For dusty gas streams, an inlet filter should be installed to protect the pump.